 Measures of inverter
• If a large value is set in Pr.72 PWM frequency selection, decrease the Pr.72 setting. (Noise from the motor increases.)
• Increase the setting of speed (torque) setting filter Pr.822, Pr.832 (Pr.826, Pr.836).
NOTE
• As changing the speed (torque) setting filter will affect the response level of the inverter to the command, adjust the setting
by looking at the machine movement.
 Measures of option
• Install the line noise filter FR-BLF (FR-BSF01 for the 3.7K or lower).
NOTE
• Refer to the Instruction Manual (Detailed) of the inverter for details of measures for EMI.
5.5

Specifications

Frequency setting resolution: 0.01 Hz/0 to 60 Hz (-10 to +10 V) (0.015 Hz/0 to 60 Hz when option is not mounted)
Torque setting resolution: 0.024%/0 to 100% (-10 to +10 V) (0.1%/0 to 100% when option is not mounted)
Input resistance: 10 k
Maximum input voltage: 20 VDC