Motor temperature monitor output

The motor temperature can be monitored using PU, DU, terminal AM, terminal FM/CA, RS-485 communication, or each output
option. (Set Pr.407 Motor temperature detection filter  "9999")
Set "46" in the following parameters.
• Pr.52 Operation panel main monitor selection, Pr.54 FM/CA terminal function selection, Pr.158 AM terminal function
selection (Refer to the Instruction Manual (Detailed) of the inverter for details.)
• Pr.306 Analog output signal selection, Pr.310 Analog meter voltage output selection (Refer to the Instruction Manual
of FR-A8AY for details.)
• Pr.838 DA1 terminal function selection (Refer to
Set the following parameter to adjust the motor temperature on the full scale.
Pr.
Pr.
group
*1
M046
Reference motor temperature
751
*1
Setting can be made only when the FR-A8AZ is mounted.
page
22)
Name
Setting range
1 to 200
Minimum
setting
Initial value
increments
1
150