Slip Compensation - Mitsubishi Electric 800 Series Instruction Manual

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

6.3.7

Slip compensation

When Pr.407 Motor temperature detection filter  "9999", slip compensation is enabled under vector control for the motor
with an encoder. The slip frequency is compensated by Pr.326 Motor temperature feedback reference and the detected
temperature.
When using the motor constant set by offline auto tuning or set directly, set in Pr.326 the motor temperature for when the motor
constant (R2) was determined.
Pr.
Pr.
group
Motor temperature feedback
*1
G062
326
reference
*1
Setting can be made only when the FR-A8AZ is mounted.
NOTE
• When Pr.407  "9999", magnetic flux observer under vector control for the motor with an encoder (Pr.95 Online auto
tuning selection = "2") is invalid.
Initial
Name
value
9999
Minimum
Setting
setting
range
increments
Set the motor temperature for when the
0 to 150
motor constant (R2) was determined.
1
The slip frequency is compensated with a
9999
reference temperature of 75.
MOTOR THERMISTOR INTERFACE
Description
47
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a8az

Table of Contents