Replacement Of Output Ics (X8Gn, X8Gi Printed Board) - Toshiba TH180 Maintenance Manual

Industrial robot
Hide thumbs Also See for TH180:
Table of Contents

Advertisement

4)
Mount the fuse holder. (Push and turn the holder to the right by 90°. It will be
locked.)
1) Turn on the controller main power and make sure that no error will occur.

3.3.6 Replacement of Output ICs (X8GN, X8GI Printed Board)

If the current exceeding the specified current has run through the output unit, the ICs
on the X8GC, X8GN (X8GI) printed board is damaged.
When this happens, replace the ICs.
Before the replacement, examine and identify an fault circuit, remedy the cause, then
replace the ICs.
The relationship between the output ICs [2] and output signals is shown below.
[1] Output IC
I/O printed board(X8GN/X8GI)
64
MAINTENANCE MANUAL
[2] Output IC U3
User output signal:
DOUT1 ~ DOUT8
Connector: OUTPUT
[2] Output IC U4
User output signal:
DOUT9 ~ DOUT16
Connector: OUTPUT
[2] Output IC U5
User output signal:
DOUT17 ~ DOUT24
Connector: OUTPUT
[2] Output IC U6
User output signal:
DOUT25 ~ DOUT32
Connector: OUTPUT