HANDLE MACHINE READY FOR INSTALLATION OF ATTACHMENT
Proportional control rolling switch.
The 2nd-line attachment proportional switch operates the 2nd
attachment circuit (e.g. clamshell rotation). The 2nd-line attach-
ment proportional switch is a roller proportional control switch.
Rolling the switch up produces rotation in one direction, rolling
down produces rotation in the opposite direction. Slight move-
ment of the roller will give slight movement of the clamshell; full
movement of the roller will give faster movement of the clam-
shell.
REMARK
If installing 2nd attachment as a field kit, ask the distributor to
change monitor setting to allow 2 attachment mode.
BREAKER MODE SWITCH
When operating breaker using breaker switch, lock the pedal with the lock pin to avoid accidental oper-
ation.
The breaker mode switch operates the breaker.
Press the breaker mode switch to operate breaker and release
to stop.
METHOD FOR CHANGE-OVER AND CONNECT HYDRAULIC CIRCUIT FOR
MACHINE READY FOR INSTALLATION OF ATTACHMENT
NOTICE
The return circuit when a breaker is installed must return directly to the return filter, so do not use it
in the mode other than B mode.
The standard set pressure of the safety valve of the service valve is 20.6 MPa {210 kg/cm
select B mode set at the shipment from the plant and it becomes 27.4 MPa {280 kg/cm
or ATT/E mode is selected. Depending on the attachment, it may be necessary to adjust the pres-
sure. Ask your Komatsu distributor for the adjustment.
SWITCHING THE HYDRAULIC CIRCUIT
Depending on the type of attachment, set the working mode on the monitor as follows.
The hydraulic circuit and the set pressure of the safety valve in the service valve switch according to the
working mode selected.
Attachment
Breaker or attachment with
one-way circuit
6-18
k
k
WARNING
Working mode
Return circuit automatically
B mode
does not pass through con-
ATTACHMENTS AND OPTIONS
Hydraulic circuit
becomes the circuit that
trol valve
2
} if you
2
} when ATT/P
Set pressure of safety valve
of service valve
When shipped from factory:
20.6 MPa {210 kg/cm
2
}