[F] Center heater lamp / Side heater lamp (LAMP1/LAMP2)
(1)
Take off the fuser roller unit.
P.13-11 "[B] Pressure roller unit / Fuser
roller unit"
(2)
Remove 2 screws on each terminal of both
center heater lamp and side heater lamp.
(3)
Pull out the center heater lamp and side
heater lamp.
Notes:
•
When installing the heater lamps, be sure
not to mix up the upper heater lamp and
the lower heater lamp.
The upper heater lamp has a coil wound
up on its center part, and the lower heater
lamp has coils wound up on its both
edges.
•
When installing the heater lamps, be sure
to face up their weld sides.
•
Do not touch the lamps directly with your
hands.
•
The connector on each end of the har-
ness which connects to the center heater
lamp has a small screw hole. The con-
nector on each end of the harness which
connects to the side heater lamp has a
big one.
e-STUDIO163/203
FUSER / EXIT UNIT
Upper side : center heater lamp
Lower side : side heater lamp
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
13 - 16
07/02
Fig. 13-21
Center heater lamp
Side heater lamp
Fig. 13-22
Weld
Fig. 13-23