Mismatch between the cable outer diameter and the rubber fitting may degrade the Ingress
Protection Rating of the device.
To avoid damaging the rubber fitting, do not route a cable with a crimped OT terminal
directly through the rubber fitting.
Do not adjust the cable when the locking cap is tightened. Otherwise, the rubber fitting
will shift, which affects the Ingress Protection Rating of the device.
Figure 5-8 Selecting the rubber fitting
Step 4 Remove an appropriate length of the jacket and insulation layer from the AC output power
cable using a wire stripper.
Ensure that the jacket is in the maintenance compartment.
Figure 5-9 Three-core cable (excluding the ground cable and neutral wire)
(A) Core wire