(1) Insulation shell
Use the positive and negative metal contacts and DC connectors supplied with the SUN2000.
Using other models of positive and negative metal contacts and DC connectors may result in
serious consequences. The caused device damage is not covered under any warranty or
service agreement.
Procedure
Step 1 Prepare positive and negative connectors.
Figure 5-18 Crimping tool (H4TC0003)
(1) Locator
Issue 11 (2019-06-08)
Figure 5-17 Negative connector
The metal contacts supplied with the DC connectors are either cold forming contacts or
stamping forming contacts. Choose the crimping tools that fit the metal contact types. Do
not mix up the tools.
Crimp the metal cold forming contacts using crimping tool UTXTC0005 (Amphenol,
recommended) or H4TC0001 (Amphenol).
Crimp the metal stamping forming contacts using crimping tool H4TC0003 (Amphenol,
recommended), H4TC0002 (Amphenol), PV-CZM-22100 (Staubli), or PV-CZM-19100
(Staubli). When choosing PV-CZM-22100 or PV-CZM-19100, do not use the locator.
Otherwise, metal contacts would be damaged.