Manager then expand the Modems tab.The MultiTech single port Modems will appear in the
list as shown below.
Step 13: Configure Stratagy using eManager
When the fax-modem card has been installed, the Stratagy software must be configured for the
modem to function.
1. Login to eManager, connect to the system.
2. Select Advanced Configuration > System > VM Serial ports.
3. For the COM port(s) the modem card(s) occupy, click on the drop arrow in the Assign As
column and select FAX. The example below shows a system with two modems.
4. Enter the PDN of the single line port in the Target Phone Number/Fax DN: field for each
modem installed. The modem and the PDN must match this entry. In the example below
COM3 is PDN 2201.
5. You must restart the Stratagy VM system for the changes to take effect.
Micro MAS Installation Guide
4/07