 Network number setting (Pr.436)
Set the inverter network number in Pr.436.
Pr.
436
IP address 3

The initial value after all parameters have been cleared with the FR-A8NCG installed.

The setting range of Pr.436 is "0 to 255", but its active range is "1 to 254".
Out-of-range setting values are invalid because such values cannot be transmitted to the master station.
 Station number setting (Pr.437)
Specify the inverter station number in Pr.437.
Pr.
437
IP address 4

The initial value after all parameters have been cleared with the FR-A8NCG installed.

The setting range of Pr.437 is "0 to 255", but its active range is "1 to 254".
Out-of-range setting values are invalid because such values cannot be transmitted to the master station.
NOTE
• Set a unique station number. (If different devices have the same station number, communication cannot be performed
properly. If an error occurs due to a duplicated number, assign the station number correctly, then reset the master or
the inverter power.)
• Station numbers do not have to be consecutive numbers.