Mitsubishi Electric CC-Link IE TSN FR-A8NCG Instruction Manual page 83

Table of Contents

Advertisement

Item
Second parameter changing


When "100" is set in Pr.52 Operation panel main monitor selection, set frequency is monitored during a stop and output frequency
is monitored during running.

When position control is selected for the FR-A800 series, the number of pulses is monitored when Pr.430 ≠ "9999".

Displayed increments differ according to the combination of Pr.37, Pr.144, and Pr.811. (Pr.811 is only available for the FR-A800
series.) For the details, refer to the Instruction Manual (Detailed) of the inverter.

Write data is in hexadecimal, and only two digits are valid. (The upper two digits are ignored.)

Differs according to capacities.

Setting from remote registers (RWw0) can be made.

Turning OFF the power supply while clearing parameters with H5A5A or H55AA sets back the communication parameter settings back
to the initial values.

Reading or writing is available when the link parameter extended setting = "1 or 9".

Gain frequencies can be written using Pr. 125 (instruction code H99) and Pr. 126 (instruction code H9A) also.
NOTE
• When the 32-bit parameter setting or monitor description are read and the read value exceeds HFFFF, the reply data
will be HFFFF.
82
Details of remote input and output signals
Read/
Code
write
number
Read or write of bias and gain parameters (instruction codes H5E to H61 and HDE to
Read
H6C
HE1 with the link parameter extended setting = "1", H11 to H23 and H91 to HA3 with the
link parameter extended setting = "9").
H00: Frequency
H01: Analog value set in parameters
Write
HEC
H02: Analog value input from the terminal
Description
