Sharp MAX-PRO 1182 Operator's Manual page 53

Table of Contents

Advertisement

SEAL BAR
The Seal Bar needs to be extended to complete this
procedure. In order to do this, the machine needs
power and air. This will cause the Seal Bar to heat
up.
NOTE: The machine must be at normal op-
erating temperature for best results. Care
must be taken to avoid scratching the sur-
face of the Seal Bar. Use the supplied
cleaning tool for best results. Remember
to retract the Seal Bar when finished.
1. Power up the machine according and apply air to
regulator.
2. Release the E-Stop Button and press the Green
Power Button.
3. Allow Seal Bar (Shown in orange) to reach set
temperature.
4. Access the Service Screen from the Main
Screen. The Service Screen is passcode protect-
ed. See Supervisor to gain access.
MAX-PRO Operator Manual
SECTION 3 - SET-UP & OPERATION
CLEANING
Extended Seal Bar
3-13
5. Press the Extend Seal Bar Button to change the
state of the Seal Bar.
6. Wear PPE - Heat Resistant Gloves.
7. NEVER use any metallic utensils on the surface
of Seal Bar. Use the Cleaning Wand (Sharp P/N
704173-01) to remove any residue accumulated
on the Seal Bar.
8. Press the Seal Bar Retracted Button to retract
the Seal Bar.
9. Return to Main Menu.
Original Printed in English