Huawei TaiShan 200 Product White Paper page 16

Hide thumbs Also See for TaiShan 200:
Table of Contents

Advertisement

TaiShan 200 Server
White Paper (Model 2180)
Indicator
network
port
UID indicator
PSU indicator
SAS/SATA Drive Indicators
Figure 4-6
Figure 4-6 SAS/SATA drive indicators
Issue 02 (2020-06-22)
Connection status
indicator
shows the SAS/SATA drive indicators.
Copyright © Huawei Technologies Co., Ltd.
State Description
● Steady green: The network port is
properly connected.
● Off: The network port is not connected.
The UID indicator helps identify and locate
a device.
● Off: The device is not being located.
● Blinking blue (blinking 255 seconds):
The device has been located and is
differentiated from other devices that
have also been located.
● Steady blue: The device is being
located.
NOTE
You can turn on, turn off, or blink the UID
indicator by pressing the UID button or
remotely running a command on the iBMC CLI.
● Steady green: The power input and
output are normal.
● Steady orange: The input is normal, but
no power output is supplied due to
overheat protection, overcurrent
protection, short circuit protection,
output overvoltage protection, or some
component failures.
● Blinking green at 1 Hz:
– The input is normal, the server is
standby.
– The input is overvoltage or
undervoltage. For details, see
TaiShan Rack Server iBMC Alarm
Handling
.
● Blinking green at 4 Hz: under online
PSU firmware upgrade.
● Off: No power is supplied.
4 Hardware Description
13