Mitsubishi Electric 800 Series Installation Manualline page 51

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Para-
Name
meter
NET Y1 output
193
selection
NET Y2 output
194
selection
NET Y3 output
195
selection
NET Y4 output
196
selection
Display corrosion
198
level
Parameter 200 to 299
Para-
Name
meter
232 to
Multi-speed setting
239
(speed 8 to speed 15)
Soft-PWM operation
240
selection
Analog input display
241
unit switchover
Cooling fan
244
operation selection
245
Rated slip
Slip compensation
246
time constant
Constant output
range slip
247
compensation
selection
Earth (ground) fault
249
detection at start
250
Stop selection
Output phase loss
251
protection selection
Life alarm status
255
display
Inrush current limit
256
circuit life display
Control circuit
257
capacitor life display
Main circuit
258
capacitor life display
Main circuit
259
capacitor life
measuring
PWM frequency
260
automatic
switchover
Power failure stop
261
selection
Initial
Setting Range
*1
Value
0, 1, 3, 4, 7, 8,
11 to 16, 20, 24
9999
to 26, 30 to 36,
38 to 41, 44 to
48, 56, 57, 60 to
64, 70, 80, 81,
84, 90 to 93, 95,
98 to 101, 103,
9999
104, 107, 108,
111 to 116, 120,
124 to 126, 130
to 136, 138 to
141, 144 to 148,
156, 157, 160 to
164, 170, 180,
9999
181, 184, 190 to
193, 195, 198,
199, 206, 211 to
213, 242 [E800-
(SC)E], 306,
9999
311 to 313, 342
[E800-(SC)E],
9999
1
(1 to 3)
Initial
Setting Range
*1
Value
0 to 590 Hz,
9999
9999
0, 1
1
0
0, 1
1
0, 1
0% to 50%,
9999
9999
0.5 s
0.01 to 10 s
9999
0, 9999
Gr.1: 0
0, 1
Gr.2: 1
0 to 100 s, 1000
9999
to 1100 s, 8888,
9999
0, 1
1
0
(0 to 879)
100%
(0% to 100%)
100%
(0% to 100%)
100%
(0% to 100%)
0, 1
0
10
0, 10
0
0 to 2
Para-
Name
meter
Terminal 4 input
267
selection
Monitor decimal
268
digits selection
269
Parameter for manufacturer setting. Do not set.
Stop-on-contact
270
control selection
Stop-on contact
excitation current
275
low-speed scaling
factor
PWM carrier
276
frequency at stop-on
contact
Stall prevention
277
operation current
switchover
Brake opening
278
frequency
Brake opening
279
current
Brake opening
280
current detection
time
Brake operation time
281
at start
Brake operation
282
frequency
Brake operation time
283
at stop
Deceleration
284
detection function
selection
Overspeed detection
frequency
285
Speed deviation
excess detection
frequency
286
Droop gain
Droop filter time
287
constant
Inverter output
289
terminal filter
Monitor negative
290
output selection
Automatic
292
acceleration/
deceleration
Acceleration/
293
deceleration
separate selection
Frequency change
295
increment amount
setting [E800]
296
Password lock level
Password lock/
297
unlock
Frequency search
298
gain
Rotation direction
299
detection selection
at restarting
PARAMETER LIST
Initial
Setting Range
*1
Value
0
0 to 2
9999
0, 1, 9999
0
0, 1, 11
0% to 300%,
9999
9999
9999
0 to 9, 9999
0, 1
0
3 Hz
0 to 30 Hz
130%
0% to 400%
0.3 s
0 to 2 s
0.3 s
0 to 5 s
6 Hz
0 to 30 Hz
0.3 s
0 to 5 s
0
0, 1
9999
0 to 30 Hz, 9999
0% to 100%
0%
0.3 s
0 to 1 s
5 to 50 ms,
9999
9999
0, 1, 4, 5, 8, 9,
0
12, 13
0, 1, 7, 8, 11
0
0
0 to 2
0, 0.01, 0.1, 1,
0
10,
0 to 6, 99, 100
9999
to 106, 199,
9999
(0 to 5), 1000 to
9999
9998, 9999
0 to 32767,
9999
9999
0
0, 1, 9999