Mitsubishi Electric 800 Series Installation Manualline page 55

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Para-
Name
meter
Starting magnetic
pole position
721
detection pulse
width
Motor inertia
724
(exponent)
Motor protection
725
current level
Device instance
728
number (Upper 3
digits) [E800-(SC)EPA]
Device instance
729
number (Lower 4
digits) [E800-(SC)EPA]
Second motor
starting resistance
737
tuning compensation
coefficient 2
Second motor
738
induced voltage
constant (phi f)
Second motor Ld
739
decay ratio
Second motor Lq
740
decay ratio
Second motor
starting resistance
741
tuning compensation
coefficient 1
Second motor
magnetic pole
742
detection pulse
width
Second motor
743
maximum frequency
Second motor inertia
744
(integer)
Second motor inertia
745
(exponent)
Second motor
746
protection current
level
759
PID unit selection
Operation panel
774
monitor selection 1
Operation panel
775
monitor selection 2
Operation panel
776
monitor selection 3
Operation frequency
779
during
communication error
Acceleration time in
*3
791
low-speed range
Deceleration time in
*3
792
low-speed range
Initial
Setting Range
*1
Value
0 to 6000 μs,
9999
9999
9999
0 to 7, 9999
100% to 500%,
9999
9999
0
0 to 419
0
0 to 9999
0% to 200%,
9999
9999
0 to 5000 mV
9999
(rad/s), 9999
0% to 100%,
9999
9999
0% to 100%,
9999
9999
0% to 200%,
9999
9999
0 to 6000 μs,
9999
9999
0 to 400 Hz,
9999
9999
9999
10 to 999, 9999
9999
0 to 7, 9999
100% to 500%,
9999
9999
9999
0 to 43, 9999
[E800]
[E800-(SC)EPB]
9999
1 to 3, 5 to 14,
17 to 20, 23 to
33, 35, 38, 40 to
42, 44, 45, 50 to
57, 61, 62, 64,
65, 67, 91, 97,
9999
100, 9999
[E800-(SC)EPA]
1 to 3, 5 to 14,
17 to 20, 23 to
33, 35, 38, 40 to
42, 44, 45, 50 to
57, 61, 62, 64,
9999
65, 67, 83, 91,
97, 100, 9999
0 to 590 Hz,
9999
9999
0 to 3600 s,
9999
9999
0 to 3600 s,
9999
9999
Parameter 800 to 999
Para-
Name
meter
Control method
800
selection
801
Output limit level
Pre-excitation
802
selection
Constant output
range torque
803
characteristic
selection
Torque command
804
source selection
Torque command
805
value (RAM)
Torque command
806
value (RAM,
EEPROM)
807
Speed limit selection
808
Speed limit
Reverse-side speed
809
limit
Torque limit input
810
method selection
Set resolution
811
switchover
Torque limit level
812
(regeneration)
Torque limit level
813
(3rd quadrant)
Torque limit level
814
(4th quadrant)
815
Torque limit level 2
Torque limit level
816
during acceleration
Torque limit level
817
during deceleration
820
Speed control P gain 1
Speed control
821
integral time 1
822
Speed setting filter 1
Speed detection filter
*4
823
1
Torque control P
824
gain 1 (current loop
proportional gain)
Torque control
integral time 1
825
(current loop integral
time)
826
Torque setting filter 1
Model speed control
828
gain
830
Speed control P gain 2
Speed control
831
integral time 2
832
Speed setting filter 2
Speed detection filter
*4
833
2
PARAMETER LIST
Initial
Setting Range
*1
Value
0 to 5, 9, 10 to
40
12, 19, 20, 40
0% to 400%,
9999
9999
0
0, 1
0
0 to 2, 10
0
0, 1, 3 to 6
1000%
600% to 1400%
1000%
600% to 1400%
0
0, 1
Gr.1: 60 Hz
0 to 400 Hz
Gr.2: 50 Hz
0 to 400 Hz,
9999
9999
0
0 to 2
0
0, 10
0% to 400%,
9999
9999
0% to 400%,
9999
9999
0% to 400%,
9999
9999
0% to 400%,
9999
9999
0% to 400%,
9999
9999
0% to 400%,
9999
9999
60%
0% to 1000%
0.333 s
0 to 20 s
9999
0 to 5 s, 9999
0.001 s
0 to 0.01 s
0% to 500%
100%
0 to 500 ms
5 ms
9999
0 to 5 s, 9999
100 rad/s
0 to 1000 rad/s
0% to 1000%,
9999
9999
9999
0 to 20 s, 9999
9999
0 to 5 s, 9999
0 to 0.01 s,
9999
9999
49

Advertisement

Table of Contents
loading

Table of Contents