PARAMETER LIST
Para-
Name
meter
Multiple rating
570
setting [3-phase]
Holding time at a
571
start
Second motor online
574
auto tuning
Output interruption
575
detection time
Output interruption
576
detection level
Output interruption
577
cancel level
Traverse function
592
selection
Maximum amplitude
593
amount
Amplitude
compensation
594
amount during
deceleration
Amplitude
compensation
595
amount during
acceleration
Amplitude
596
acceleration time
Amplitude
597
deceleration time
Parameter 600 to 699
Para-
Name
meter
First free thermal
600
reduction frequency
1
First free thermal
601
reduction ratio 1
First free thermal
602
reduction frequency
2
First free thermal
603
reduction ratio 2
First free thermal
604
reduction frequency
3
Motor permissible
607
load level
Second motor
608
permissible load
level
PID set point/
609
deviation input
selection
PID measured value
610
input selection
Acceleration time at
611
a restart
Inverter output fault
631
detection enable/
disable selection
Brake opening
639
current selection
Brake operation
640
frequency selection
48
Initial
Setting Range
*1
Value
2
1, 2
9999
0 to 10 s, 9999
0
0, 1
0 to 3600 s,
1 s
9999
0 Hz
0 to 590 Hz
900% to 1100%
1000%
0
0 to 2
10%
0% to 25%
0% to 50%
10%
10%
0% to 50%
5 s
0.1 to 3600 s
0.1 to 3600 s
5 s
Initial
Setting Range
*1
Value
0 to 590 Hz,
9999
9999
100%
1% to 100%
0 to 590 Hz,
9999
9999
100%
1% to 100%
0 to 590 Hz,
9999
9999
150%
110% to 250%
110% to 250%,
9999
9999
2
2 to 5
3
2 to 5
0 to 3600 s,
9999
9999
0
0, 1
0, 1
0
0
0, 1
Para-
Name
meter
Speed smoothing
653
control
Speed smoothing
654
cutoff frequency
Increased magnetic
excitation
660
deceleration
operation selection
Magnetic excitation
661
increase rate
Increased magnetic
662
excitation current
level
Regeneration
665
avoidance frequency
gain
SF-PR slip amount
adjustment
673
operation selection
[200/400 V class]
SF-PR slip amount
674
adjustment gain
[200/400 V class]
User parameter auto
675
storage function
selection
Deceleration check
690
time
Second free thermal
692
reduction frequency
1
Second free thermal
693
reduction ratio 1
Second free thermal
694
reduction frequency
2
Second free thermal
695
reduction ratio 2
Second free thermal
696
reduction frequency
3
698
Speed control D gain
699
Input terminal filter
Parameter 700 to 799
Para-
Name
meter
Maximum motor
702
frequency
Induced voltage
706
constant (phi f)
Motor inertia
707
(integer)
711
Motor Ld decay ratio
712
Motor Lq decay ratio
Starting resistance
717
tuning compensation
coefficient 1
Starting resistance
720
tuning compensation
coefficient 2
Initial
Setting Range
*1
Value
0%
0% to 200%
20 Hz
0 to 120 Hz
0, 1
0
0% to 40%,
9999
9999
100%
0% to 200%
100%
0% to 200%
9999
2, 4, 6, 9999
100%
0% to 500%
9999
1, 9999
0 to 3600 s,
1 s
9999
0 to 590 Hz,
9999
9999
100%
1% to 100%
0 to 590 Hz,
9999
9999
100%
1% to 100%
0 to 590 Hz,
9999
9999
0%
0% to 100%
5 to 50 ms,
9999
9999
Initial
Setting Range
*1
Value
0 to 400 Hz,
9999
9999
0 to 5000 mV
9999
(rad/s), 9999
9999
10 to 999, 9999
0% to 100%,
9999
9999
0% to 100%,
9999
9999
0% to 200%,
9999
9999
0% to 200%,
9999