Last Clear Peaks
Displays the time for which this unit has been collecting the peak
usage and latency information. In other words, this is the time elapsed
since last Clear Peaks action (see below) or since the last reboot of the
unit. Possible readings are: 1 sec, 2 sec, 5 sec, 10 sec, 30 sec, 1 min,
2 min, 5 min, 10 min, 30 min, 1 hr, 2 hrs, 5 hrs, 10 hrs, 1 day, 2 days, 5
days, 10 days, 30 days, 1 month, 2 months, 5 months, 10 months, >30
months.
Clear Peaks
Resets the unit‟s Usage-IN Peak, Usage-OUT Peak and Latency-Peak
readings.
Clear CV Counts
Resets the unit‟s CV counters for both Line ports. Also clears the CV
counters in the Line tab.
Clear All
Clears the CV counters (Main and Line tabs), Peak Usage and Peak
Latency information (Main tab), Ethernet Statistics Counters for all
ports (Port Statistics tab) and Priority Queues' counters (Passed and
Lost tabs).

Unit Location

Rack (use is optional)
Identifies the rack or cabinet (1 to 64) in which the unit is located.
This information may be utilized on the NMS (Network
Management System).
Shelf (use is optional)
Identifies the shelf (1 to 64) in which the unit is located.
information may be utilized on the NMS.
Slot (use is optional)
Identifies the slot position within the shelf (1 to 15) in which the unit
is located. This information may be utilized on the NMS.
Copyright  GE Multilin Inc. 2010-2012
342-86400-498PS
Issue 1.2
April 2012
Page 75