5-17. RF OUTPUT POWER FLATNESS ADJUSTMENT (Cont'd)
17. On the OUT, press [SHIFT] [GHz][1] [3] [Hz] [SHIFT][MHz] [1] [2] [Hz] [SHIFT][kHz] [2] [2]
[Hz] to access Cal Constant 13. Adjust Cal Constant 13 for a power meter indication of P. Adjust
A25R108 (LOFS) (Figure 5-63) for a 0 dBin indication on the power meter.
AM OFFSET
18. On the OUT, press [CW] [4]
FACTOR % dial for the 4.5 GHz CAL FACTOR indication on the power sensor. Adjust the OUT's
rotary knob for a 0 dBin indication on the power meter.
19. On the OUT, press [SHIFT]
Adjust Cal Constant 43 for no more than 0.05 dB change in the power meter indication when
turning
[AM]
on and off.
AOC CAL CONSTANTS
20. On the OUT, press [SHIFT][PWRSWP] [0] [dBm] to decouple the RF attenuator and the ALC and
to set the ALC at 0 dBin. The RF attenuator should also be at 0 dB. If it is not, use the [a.] step key
to set it to 0. Press
21. On the OUT, press [SHIFT]
Adjust Cal Constant 42
22. On the OUT, press [SHIFT][PWRSWP]
[SHIFT]
[GHz] [4] [0] [Hz] [SHIFT] [ENTRY OFF]
Constant 40 so the OUT's POWER dBin display shows —20.00 dBm.
23. On the OUT, press [CW] [1]
stant 39 and adjust Cal Constant 39
If adjustments of the Cal Constants were made in this procedure, the Cal
Constants data stored in the "working memory" should be copied into
the "protected memory" by pressing [SHIFT][MHz][1] [4] [Hz] [SHIFT]
[kHz] [5] [3] [4] [9] [Hz]. Wait for "CALIBRATION RESTORED" to be
displayed in the ENTRY DISPLAY, then press [INSTRPRESET].
HP 8340B/41B
[5] [GHz][POWER LEVEL] [0] [dBm].Set the power meter's CAL
[.]
[GHz] [4] [3] [Hz] [SHIFT]
to turn the AM on.
[AM]
[0Hz] [4] [2] [Hz] [SHIFT]
the OUT's POWER dBm display shows 0.00 dBm.
50
[2]
[-]
[5] [GHz].Press [SHIFT][0Hz] [3] [9]
[.]
the OUT's POWER dBin display shows —20.00 dBin.
50
NOTE
[ENTRYOFF] to access Cal Constant 43.
[ENTRYOFF] to access Cal Constant 42.
[0] [dBm]to set the ALC level to —20 dBin. Press
to access Cal Constant 40 and adjust Cal
[Hz]
to access Cal Con-
Adjustments
5-119/5-120