Installation Conditions For Indoor Units (Hydrokit Or All In One Unit); Minimum Distances For Indoor Units (Hydrokit Or All In One Unit) - Panasonic Aquarea WH-ADC0309J3E5 Planning And Installation Manual

Air-to-water heat pumps
Hide thumbs Also See for Aquarea WH-ADC0309J3E5:
Table of Contents

Advertisement

5.2.2.5 Installation conditions for indoor units (hydrokit or All in One unit)

The installation conditions for the indoor units are as follows:
● The indoor units are designed for indoor installation only and must not be installed
outdoors.
● The installation space must be dry and frost-free and the installation location easily
accessible for maintenance work.
● Pipes, cables and wall bushings should be arranged in a useful manner and using the
shortest path (electrical cables, refrigerant and heating water pipes).
● Ensure good air circulation in the installation room.
● There must not be any heat or vapour sources near the indoor unit. Even laundries or
other rooms with high humidity are not suitable, because high humidity causes rusting
and can damage the device.
● The condensed water from the condensation drain of the indoor unit should be able to
flow away freely without obstacles, because incorrect draining can cause damage.
● Development of noise in the room should be taken into account (→
p.
97).
● Do not mount the device near the door.
● Maintain the minimum distances (→
p.
107).
● The hydrokit must be installed vertically on the wall, where the wall should be strong
and solid, so that no vibration occurs.
● The All in One unit must be installed standing vertically on the floor, where the floor
should be strong enough to withstand the weight of the water-filled unit.
● In case electrical devices are installed on wooden buildings with metal strips or cable
cleats, no electrical contacts are allowed between device and building according to the
corresponding standards for electrical work.

5.2.2.6 Minimum distances for indoor units (hydrokit or All in One unit)

Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
All in One unit J or H generation
1
2
2
3
2
5.2.2.6 Minimum distances (indoor units),
Minimum distances All in One unit J generation
1 Minimum distance: 350 mm
2 Minimum distance: 100 mm
3 Minimum distance: 700 mm
Minimum distances All in One unit H generation
1 Minimum distance: 300 mm
2 Minimum distance: 100 mm
3 Minimum distance: 700 mm
Note: Schematic figure for explanation purposes only.