Functions And Technical Data; Product Features - Panasonic Aquarea WH-ADC0309J3E5 Planning And Installation Manual

Air-to-water heat pumps
Hide thumbs Also See for Aquarea WH-ADC0309J3E5:
Table of Contents

Advertisement

Model code for mono-bloc units
Device type
Construction
Series
Operating mode
Nominal
heating capacity
Device
generation
Backup heater
capacity
Market
Power supply
1 The devices of the Aquarea HT series can only be used for heating mode and have no cooling function.
2 The available capacities differ according to the series. An overview is given in the model range (→
p.
8).
3 J generation requires refrigerant R32, H generation requires refrigerant R410A, F generation requires refrigerant R407C.
4.6

Functions and technical data

4.6.1 Product features

Energy efficiency and environment friendliness
● Up to 80 % of the energy is obtained from the ambient air for greater energy efficiency
● COP of 5.33 for the single phase 3 kW bi-bloc and All in One systems or COP of
5.08 for the single-phase 5 kW mono-bloc system for A7 / W35 (all High Performance
series, J Generation)
● Inverter technology allows for a demand-controlled power output of the device and
thus contributes to energy savings
● Environmentally friendly refrigerants (R32 and R410A for Aquarea High Performance
and T-CAP, R407C for Aquarea HT)
● All systems are fitted with a high-efficiency pump
High Comfort
● Optimum control
● Models available for heating only (HT) or for heating and cooling (High Performance
and T-CAP)
● Optimised performance based on return water temperature
● Integrated control of the hot water tank and heating
● 24-hours timer with mode control
● Model WH-ADC0309J3E5B complete with all necessary equipment for control of two
individual heating zones
● Extremely compact model WH-ADC0309J3E5C optimised for combination with
optional Heat recovery Ventilation Unit (HRV)
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
WH
WH: Air-to-water
heat pump
M: Mono-bloc outdoor unit
D: Aquarea High Performance, X: Aquarea T-CAP,
H: Aquarea HT
C: Heating and cooling, F: Heating only
1
05 to 16 (corresponds to 5 to 16 kW)
2
... G, H, J ...
3
3: 3 kW, 6: 6 kW, 9: 9 kW
E: Europe
5: Single phase, 8: Three phase
M
D
C
09
Product Description
J
3
E
5
1 Model range,
4
27

Hide quick links:

Advertisement

Table of Contents
loading