6.8.2.3 Brief Overview of the external interfaces

All in One unit, hydrokit and mono-bloc systems J or H Generation
Main PCB
Optional PCB CZ-NS4P
Swimming pool pump
Pump for heating circuit 1
Pump for heating circuit 2
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
CN1
Optional thermostat 2
L
N Cool Heat L
1
2
3
CN201
1
2
3
Solar station
4
5
Error
signal
6
1
2
3
CN205
4
1
2
CN2
1
2
3
4
5
6
1
2
3
4
C O N C O N
H C N L
2-way valve 3-way valve
Optional
thermostat 1
Optional thermostat 1
Mixing valve 1
N Cool Heat
N
O
C
4
1
2
3
4
1
2
3
CN202
CN203
CN204
CN207
3
4
5
6
1
2
3
4
5
6
1
Installation
CN6
Overload protection for
1
electric tank heater
2
Room temperature
3
sensor heating circuit 1
4
CN5
Outdoor temperature
1
sensor
2
3
Tank temperature sensor
4
CN4
1
External control
2
3
Operating unit
4
CN3
1
Bivalent heating source
2
3
Additional pumps
4
5
Electric tank heater
6
Mixing valve 2
N
O
C
4
5
6
External compressor
1
switch
2
3
Heating/ Cooling Switch
4
1
Vcc
2
3
Bit1
SG signal
4
Bit2
2
3
4
6
183