Control; Remote Controller - Panasonic Aquarea WH-ADC0309J3E5 Planning And Installation Manual

Air-to-water heat pumps
Hide thumbs Also See for Aquarea WH-ADC0309J3E5:
Table of Contents

Advertisement

Mono-bloc systems | Aquarea HT | G Generation | Single Phase | Heating only | R407C
Outdoor unit
Heating capacity / COP (A +7 °C, W 35 °C)
Heating capacity / COP (A +7 °C, W 65 °C)
Heating capacity / COP (A +2 °C, W 35 °C)
Heating capacity / COP (A +2 °C, W 65 °C)
Heating capacity / COP (A -7 °C, W 35 °C)
Heating capacity / COP (A -7 °C, W 65 °C)
ErP data for Space Heating
Seasonal energy efficiency (ηs,h)
Average climate
SCOP
Energy class
1
Seasonal energy efficiency (ηs,h)
Warm climate
SCOP
Energy class
1
Seasonal energy efficiency (ηs,h)
Cold climate
SCOP
Energy class
1
Sound power
2
Dimension
H x W x D
Net weight
Refrigerant (R407C) / CO
Eq.
3
2
Water pipe connector
Number of speeds
Pump
Input power (Min / Max)
Heating water flow (∆T=5 K. 35 °C)
Capacity of integrated electric heater
Input power
Running and starting current
Current 1
Current 2
Recommended fuse
Recommended cable size, supply 1 / 2
Outdoor ambient
Operation range
Water outlet
1 Scale from A+++ to D.
2 Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7 °C.
3 WH-MHF models are hermetically sealed.
Note:
EER and COP calculation is based in accordance to EN14511.
4.7

Control

4.7.1 Remote controller

The Aquarea heat pumps can be operated and programmed through the remote controller included
in the scope of delivery. The remote controller has a display for showing the most important
operating parameters and various control buttons for retrieving, setting, activating and deactivating
the control functions.
To combine the Aquarea heat pumps with external devices such as a solar system or
a room thermostat, the remote controller is equipped with the requisite interfaces. The
corresponding functions are only available if the accessories in question are connected and
activated (→
6.8.2 Connecting accessories, p.
In the case of bi-bloc systems, the remote controller is integrated into the hydrokit or All in One
unit, but can be removed from the device to another room for separate installation. In the case of
mono-bloc systems, the remote controller is always installed separately in the building. The method
for installing the remote controller is identical in both cases (→
remote controller, p.
Depending on the device generation (F, G, H, J ...), the heat pumps are equipped with various
remote controllers that provide different functions.
While the same remote controller is used for all models of one generation, all functions of the
remote controller are not directly available for all models of that generation. (For example, the
domestic hot water mode is directly available in bi-bloc systems with All in One unit having an
internal domestic hot water tank, while in bi-bloc systems with standard hydrokit and external
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
kW / –
kW / –
kW / –
kW / –
kW / –
kW / –
W35 / W55
%
W35 / W55
W35 / W55
W35 / W55
%
W35 / W55
W35 / W55
W35 / W55
%
W35 / W55
W35 / W55
dB(A)
mm
kg
kg / t
Inch
W
l/min
kW
kW
A
A
A
A
mm²
Heat
°C
Heat
°C
4.7.2 External interfaces (inputs/outputs), p.
181).
184).
Single phase
WH‑MHF09G3E5
9.00 / 4.64
9.00 / 2.48
9.00 / 3.45
9.00 / 2.06
9.00 / 2.74
9.00 / 1.79
153 / 125
3.90 / 3.20
A++ / A++
191 / 156
4.84 / 3.97
A+++ / A+++
137 / 116
3.50 / 2.97
A+ / A+
1,410 x 1,283 x 320
151
1.92 / 3.406
R 1¼
7
25.8
3
1.94
9.3
28.5
13.0
30 / 30
3 x 4.0 or 6.0 / 3 x 4.0
-20 ~ +35
25 ~ 65
65, →
4.8 Accessories, p.
6.8.3 Installing and connecting the
Product Description
WH‑MHF12G6E5
12.00 / 4.46
12.00 / 2.41
12.00 / 3.26
10.30 / 2.01
12.00 / 2.52
9.60 / 1.77
150 / 125
3.82 / 3.21
A++ / A++
188 / 156
4.77 / 3.97
A+++ / A+++
134 / 113
3.42 / 2.90
A+ / A+
1,410 x 1,283 x 320
151
1.92 / 3.406
R 1¼
7
34.4
6
2.69
12.8
29.0
26.0
30 / 30
3 x 4.0 or 6.0 / 3 x 4.0
-20 ~ +35
25 ~ 65
72,
59
4