Maintenance and Trouble Clearing
RU Alarms
Table 47
Node shutdown
Probable Cause
Node is shut down
Note: Reports alarm only
Table 48
Sync status changes
Probable Cause
Sync failed
Sync not connected
Out-of-sync
Desynchronization
Note: Stops all RF transmission
Table 49
IQ over Input
Probable Cause
IQ over Input ALM
Note: Stops RF transmission at port with
alarm
Table 50
VSWR alarm
Probable Cause
VSWR ALM
Note: Stops RF transmission at port with
alarm
Table 51
RX out of order
Probable Cause
RxGainALM
Note: Stops RF transmission at port with
alarm
·
Issue 1.1, May 2021
Release 1.0
Severity
Major
Severity
Major
Severity
Major
Severity
Major
Severity
Major
Corrective Action
Take no action
Corrective Action
Reestablish synchronization
Corrective Action
Reset
Corrective Action
Reset
Corrective Action
Reset