Optical Connector Cleaning
LC End Surface Cleaning
C.1
LC End Surface Cleaning
This procedure describes how to clean the Lucent Connector (LC) end surface.
Prerequisite:
■ Reel-type cleaner
Step 1
Remove the protection cap from the connector.
Step 2
Hold the connector vertically against the cleaner and rub in the direction of the arrow on the cleaning side of the
cleaner for 1-2 seconds to prevent wrinkles.
Important: Do not use the same area on the cleaner a second time. If more cleaning is needed, use a
different area on the cleaner or a new cleaner.
Caution: Do not rotate the connector while cleaning.
Figure 68
Cleaning Method
Step 3
After cleaning, promptly install in the connector or replace protection cap and store it.
Note: Install or store the connector within 15 minutes of cleaning to prevent unnecessary dirt from entering the
connector.
·