Asus AAEON SPG-M041 User Manual page 33

Iot gateway system
Table of Contents

Advertisement

Label
Interface
1
Reset
2
V1-
3
V1+
4
V2-
5
V2+
6
Ground
Ground
7
screw
Insert a small flat-bladed screwdriver in the V1-/V1+ wire-clamp screws and
loosen the screws
Insert the negative/positive DC wires into the V1-/V1+ terminals of DC1. If
power redundancy is enabled, connect DC2 in the same manner
Tighten the wire-clamp screws to secure the DC wires in place
Insert the terminal block and press it in until it is flush with the terminal block
receptor on the SPG-M041
Chapter 3 – Gateway Setup and Configuration
Connector Type
Push button
Terminal block
Terminal block
Terminal block
Terminal block
Terminal block
-
Description
Reboot: Use a pointed object to press
reset button to reboot.
Negative pole of power input 1
Positive pole of power input 1
Negative pole of power input 2
Positive pole of power input 2
Earthing point for power supply
-
22