2.2 LEDs Controlled by IE-703217-G1-EM1

Some of the LEDs mounted in the IE-V850ES-G1 are controlled by the IE-703217-G1-EM1.
For the LEDs that are controlled by the IE-V850ES-G1, refer to the IE-V850ES-G1 User's Manual (U16313E).
(1) Target RESET LED
The status of the RESET signal connected to the target system is indicated as follows.
Lit (ON):
The target system is connected and the RESET signal is active (GND level).
Unlit (OFF): Either the target system is not connected, or the RESET signal is inactive (V
(2) Target BV
LED
DD
The status of the BV
DD
Lit (ON):
The target system is connected, and voltage is being applied to the BV
Unlit (OFF): Either the target system is not connected, or voltage is not being applied to the BV
(3) Target EV
LED
DD
The status of the EV
DD
Lit (ON):
The target system is connected and voltage is being applied to the EV
Unlit (OFF): Either the target system is not connected, or voltage is not being applied to the EV
18
CHAPTER 2 PART NAMES AND FUNCTIONS
Figure 2-2. LEDs Controlled by IE-703217-G1-EM1
STATUS LED
signal connected to the target system is indicated as follows.
signal connected to the target system is indicated as follows.
User's Manual U16594EJ1V0UM
(1) Target RESET LED
(2) Target BV
LED
DD
(3) Target EV
LED
DD
LEDs controlled by IE-V850ES-G1