4.3 Probe Cable Connection

The probe cable is connected to the IE-703217-G1-EM1 at shipment. To remove the probe cable, use the
following procedure.
(1) To remove the probe cable
<1> Remove front cover 1 of the case.
<2> Remove the fixing screws from the EM1 board.
<3> Remove the probe cable fixing bracket. Proceed with caution when doing so as one end of the probe cable
fixing bracket covers the probe cable positioning mark.
<4> Remove the probe cable.
<5> Close front cover 1 of the case.
(2) To connect the probe cable
<1> Remove front cover 1 from the case.
<2> Insert the probe cable in the socket on the EM1 board.
<3> Connect the probe cable fixing bracket so that one end covers the probe cable positioning mark.
<4> Tighten the fixing screw.
<5> Close front cover 1 of the case.
28
CHAPTER 4 SETUP PROCEDURE
Figure 4-6. Probe Cable Attachment Position
IE-703217-G1-EM1 board
Probe cable
Fixing screw
User's Manual U16594EJ1V0UM
Probe cable fixing bracket
GXP-AXK/KEL board