Chapter 6 Restrictions - NEC IE-703217-G1-EM1 User Manual

Emulation board
Table of Contents

Advertisement

The following restrictions apply to the IE-703217-G1-EM1.
Permanent restrictions
(1) Clock generator
• Emulation of oscillation stabilization time after reset release
An oscillation stabilization time is inserted after reset release for the emulation target device, but no oscillation
stabilization time is inserted in the in-circuit emulator.
• Operating clock after reset
The operating clock after reset is f
be a period during which the operating clock is not initialized to f
release.)
(2) Standby mode set/release timing
The standby mode set/release timing differs in the target device and the in-circuit emulator.
When the standby mode is set, the timing difference is 1 clock or less, and when it is released, the difference is 2
to 3 clocks.
(3) Timing of reset via watchdog timer
The reset timing using WDT1, WDT2 overflow differs for the target device and the in-circuit emulator.
• Operation during break
Since various peripheral functions operate even during breaks in the in-circuit emulator, differences in the
operations of the in-circuit emulator and the target device may occur.
(However, the watchdog timer counter stops during an in-circuit emulator break.)
30

CHAPTER 6 RESTRICTIONS

/8 in the emulation target device, but in the in-circuit emulator, there may
xx
User's Manual U16594EJ1V0UM
/8. (This depends on the timing after reset
xx