Mitsubishi Electric MELSEC iQ-R Series User Manual page 41

Devicenet master/slave module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Master Function Parameters
Set the master function parameters.
Item
Constant Scan
Setting method of slave nodes
Slave Node
Node Address
Information
*1
(th)
Message Group
Connection Type
*2
Input Byte Size
*2
Output Byte Size
*2
Input Word Size
*2
Output Word Size
*2
Input Dword Size
Output Dword
*2
Size
Expected Packet
Rate
Watch Dog Time out
Production Inhibit
Time
*1 Set the number of I/O points for a single slave node within 256 bytes in total.
*2 For the sorting order of the modules stored in the buffer memory, refer to the following.
Page 88 Master function transmit/receive data area
Description
Set the link scan time. (ms)
Set a larger value than "Maximum link scan time". If "Current link scan time" is
longer than the set link scan time, the module operates according to "Current
link scan time".
Select whether to set the slave node information in engineering tool or with
information stored in the module.
Set the node address (MAC ID) of the slave node on .
Set the message group.
Select the connection type for the I/O communication.
Set the number of input byte modules.
The bit module is calculated as 8 points equaling to 1 byte module.
Set the number of output byte modules.
The bit module is calculated as 8 points equaling to 1 byte module.
Set the number of input word modules.
Set the number of output word modules.
Set the number of input double-word modules.
Set the number of output double-word modules.
Set the expected packet rate for the slave node.
When the setting value is 0 (default): 200ms
When the setting value is other than 0: The setting value -1 is the expected
packet rate (ms)
Set the action taken when a watchdog timeout occurs in the slave node.
(Default)
Same as the following timeout.
TIMEOUT
The connection times out.
The communication is manually stopped, and is not recovered until manually
restarted.
AUTO DELETE
The connection is automatically deleted.
The communication is stopped temporarily, and automatically restarted.
The output is cleared once.
AUTO RESET
Communication continues while holding the connection.
Set the production inhibit time.
The setting value varies depending on the connection type.
When the setting value is 0 (default value): 10ms
When the setting value is other than 0: The setting value -1 is the minimum
transmitting interval (ms).
Setting range
0 to 65535
(Default: 0)
• Parameter editor
• Information saved in unit
(Default: Parameter editor)
0 to 63
(Default: 0)
• (No specification)
• Node that supports UCMM, and
uses either message group 3, 2 or 1
• Node that supports UCMM, and
uses message group 1
• Node that does not support UCMM.
(Supports group 2 server only)
• Reserved node
(Default: (No specification))
• None
• Polling
• Bit strobe
• Change of state
• Cyclic
(Default: None)
0 to 255
(Default: 0)
0 to 255
(Default: 0)
0 to 128
(Default: 0)
0 to 128
(Default: 0)
0 to 64
(Default: 0)
0 to 64
(Default: 0)
0 to 65535
(Default: 0)
• Default
• Timeout
• Auto delete
• Auto reset
(Default: Default)
0 to 65535
(Default: 0)
2 PARAMETER SETTINGS
2.2 Basic Settings
2
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-rj71dn91

Table of Contents