38 CONVERTING THE GAS TYPE
CAUTION
• NEVER LOOSEN THE PHILLIPS
SCREW WHEN CONVERTING
THE GAS TYPE.
• AFTER CONVERTING THE
GAS TYPE, CHECK THE
VALVES FOR GAS LEAKS
USING SOAPY WATER.
Adjust the primary air for oven burner
The primary air is correctly set when the flame is
stable and blue/green.
Proceed as follows:
• Take down the oven burner, loosen the screw and
turn the cover clockwise or anti-clockwise.
• The correct cover position can be determined from
the following table:
Type of gas
'A' size for oven burner
G20/20 mbar
G30/29 mbar
• Tighten the screws again.
Reassembling the floor
To reassemble the floor, proceed in the opposite
order when inserting the removable floor.
4±1 mm
8±1 mm