Cage; Format Of Possible Cage Exception Messages; Cage Example 1; Cage Suggested Action 1 - HP 3PAR StoreServ 7000 Troubleshooting Manual

Hide thumbs Also See for 3PAR StoreServ 7000:
Table of Contents

Advertisement

cage

Displays drive cage conditions that are not optimal and reports exceptions if any of the following
do not have normal states:
Ports
SFP signal levels (RX power low and TX failure)
Power supplies
Cage firmware (is not current)
Reports if a servicecage operation has been started and has not ended.
Cages are supported for hardware platform

Format of Possible cage Exception Messages

Cage cage:<cageid> "Missing A loop" (or "Missing B loop")
Cage cage:<cageid>,mag:<magpos> "Magazine is <MAGSTATE>"
Cage cage:<cageid> "Power supply <X>'s fan is <FANSTATE>"
Cage cage:<cageid> "Power supply <X> is <PSSTATE>" (Degraded, Failed, Not_Present)
Cage cage:<cageid> "Power supply <X>'s AC state is <PSSTATE>"
Cage cage:<cageid> "Cage is in "servicing" mode (Hot-Plug LED may be illuminated)"
Cage cage:<cageid> "Firmware is not current"
Cage cage:<cageid> "Cage type <Model> is not supported on this platform"
Cage cage:<cageid> "Missing both A and B loops"
Cage cage:<cageid> "Cage state information is unavailable"

cage Example 1

Component -Summary Description- Qty
Cage
Cages missing A loop
Component -Identifier- -Detailed Description--
Cage
cage:1

cage Suggested Action 1

Check the connection/path to the SFP in the cage and the level of signal the SFP is receiving. An
RX Power reading below 100 µW signals the RX Power Low condition; typical readings are between
300 and 400 µW. Helpful CLI commands are showcage -d and showcage -sfp ddm.
At least two connections are expected for drive cages, and this exception is flagged if that is not
the case.
cli% showcage -d cage1
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
1 cage1 1:0:1
-----------Cage detail info for cage1 ---------
Position: ---
Interface Board Info Card0
Firmware_status
Product_Rev
State(self,partner)
VendorId,ProductId
Master_CPU
SAS_Addr
Link_Speed(DP1,DP2)
PS PSState ACState DCState Fan State Fan0_Speed Fan1_Speed
1
Missing A loop
1 0:0:1
1
8 21-23 402e 402e DCS2
Card1
Current
Current
402e
402e
OK,OK
OK,OK
HP,DCS2
HP,DCS2
Yes
No
50050CC1178EA0BE 50050CC1178E6BBE
6.0Gbps,Unknown
6.0Gbps,Unknown
RevA RevB Model FormFactor
SFF
Troubleshooting Storage System Components