Port Example 2; Port Suggested Action 2; Port Example 3; Port Suggested Action 3 - HP 3PAR StoreServ 7000 Troubleshooting Manual

Hide thumbs Also See for 3PAR StoreServ 7000:
Table of Contents

Advertisement

TX Power uW
RX Power uW

port Example 2

Component -Summary Description- Qty
Port
Missing SFPs
Component -Identifier- -Detailed Description--
Port
port:0:3:1

port Suggested Action 2

FC node-ports that normally contain SFPs will report an error if the SFP has been removed. The
condition can be checked using the showport -sfp command. In this example, the SFP in 1:1:1
has been removed from the adapter:
cli% showport -sfp
N:S:P -State- -Manufacturer- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
0:1:1 OK
0:1:2 OK
1:1:1 -
1:1:2 OK

port Example 3

cli% checkhealth -detail port
Checking port
Component -Summary Description- Qty
Port
Offline ports
-----------------------------------
1 total
Component -Identifier- --Detailed Description--
Port
-----------------------------------
1 total

port Suggested Action 3

Check the state of the port with showport. If a port is offline, it was deliberately put in that state
using the controlport offline command. Offline ports might be restored using controlport
rst.
cli% showport
N:S:P
Mode
...
0:1:1
target
0:1:2
target
...

port Example 4

Component ------------Summary Description------------ Qty
Port
Ports with mismatched mode and type
Component -Identifier- ------Detailed Description-------
Port
port:2:0:3
476
158
562
98
15
1000 10
SFP is missing
HP-F
HP-F
-
HP-F
port:0:1:2
is offline
State ----Node_WWN---- -Port_WWN/HW_Addr-
ready 2FF70002AC00006E
offline 2FF70002AC00006E
Mismatched mode and type
125
631
1258
1
8.5 No
8.5 No
- -
8.5 No
1
1
Type Protocol Label Partner FailoverState
20110002AC00006E host
20120002AC00006E free
Troubleshooting Storage System Components
No
No
Yes
No
Yes
Yes
-
-
-
No
Yes
Yes
FC
-
1:1:1
none
FC
-
1:1:2
none
1