Format Of Possible Pd Exception Messages; Pd Example 1; Pd Suggested Action 1 - HP 3PAR StoreServ 7000 Troubleshooting Manual

Hide thumbs Also See for 3PAR StoreServ 7000:
Table of Contents

Advertisement

pd
Displays Physical Drives (PDs) with states or conditions that are not optimal:
Checks for failed and degraded PDs
Checks for an imbalance of PD ports, for example, if Port-A is used on more drives than Port-B
Checks for an Unknown Sparing Algorithm. For example, when it hasn't been set
Checks for drives experiencing a high number of IOPS
Reports if a servicemag operation is outstanding (servicemag status)
Reports if there are PDs that do not have entries in the firmware DB file
Reports PDs with slow SAS connections
Reports minimum number of PDs in a cage and behind a node pair
Reports PDs that are not admitted to the system

Format of Possible pd Exception Messages

PD disk:<pdid> "Degraded States: <showpd -s -degraded>"
PD disk:<pdid> "Failed States: <showpd -s -failed">
PD -- "Sparing algorithm is not set"
PD disk:<pdid> "Disk is experiencing a high level of I/O per second: <iops>"
PD File: <filename> "Folder not found on all Nodes in <folder>"
PD File: <filename> "Folder not found on some Nodes in <folder>"
PD File: <filename> "File not found on all Nodes in <folder>"
PD File: <filename> "File not found on some Nodes in <folder>"
PD Disk:<pdID> "<pdmodel> PD for cage type <cagetype> in cage position <pos> is missing from firmware database"
PD Cage:<cageID> "There must be at least 1 PD with primary path to Node:<nodeID>"
PD Cage:<cageID> "PDs <class/rpm/cap> unbalanced. Primary path: <p_count> on Node:<nodeID>, <c_count> on Node:<nodeID>"
PD Nodes:<nodelist> "Only <count> <class/rpm/cap> PDs are attached to these nodes; the minimum is <MINDISKCNT>"
PD pd:<pdID> "PD SAS speed is <speed> instead of <speed> on both ports"
PD pd:<pdID> "PD SAS speed is <speed> instead of <speed> from port <0|1>"
PD disk:<pdWWN> "Unadmitted PD in cage position <CagePos> Type <devType>"
PD cage:<cageID>,mag:<magID> "Magazine has a failed servicemag operation"
PD cage:<cageID>,mag:<magID> "Magazine is being serviced"
PD cage:<cageID>,mag:<magID> "Magazine has an active servicemag operation in progress"

pd Example 1

Component -------------------Summary Description------------------- Qty
PD
PDs that are degraded or failed
Component -Identifier- ---------------Detailed Description-----------------
PD
disk:48
PD
disk:49
...
PD
disk:107

pd Suggested Action 1

Both degraded and failed drives show up in this report. When an FC path to a drive cage is not
working, all drives in the cage have a state of Degraded due to the non-redundant condition. Use
commands such as showpd, showpd -s, showcage, showcage -d.
cli% showpd -degraded -failed
Id CagePos Type Speed(K) State
48 3:0:0
49 3:1:0
...
107 4:9:3
cli% showpd -s -degraded -failed
Id CagePos Type -State-- -----------------Detailed_State--------------
48 3:0:0
54
Troubleshooting
Detailed State: missing_B_port,loop_failure
Detailed State: missing_B_port,loop_failure
Detailed State: failed,notready,missing_A_port
FC
10 degraded
FC
10 degraded
FC
15 failed
FC
degraded missing_B_port,loop_failure
----Size(MB)---- ----Ports----
Total
Free A
139520
115200 2:0:2* -----
139520
121344 2:0:2* -----
428800
0 -----
40
B
3:0:1*

Advertisement

Table of Contents
loading

This manual is also suitable for:

3par storeserv 7000c

Table of Contents