Blower Motor Inspection

• Check continuity between terminals as shown in the
figure.
If check result is continuity, proceed to next operation
check. If not, replace.
• Check for operation and electric current.
a. Put blower motor (1) in a soft-jawed vise.
b. Connect battery to blower motor as shown.
c. Check if blower motor operates smoothly without
noise.
d. Check if ammeter indicates the specified current.
If measured current is out of specification, replace
blower motor.
Specified current for blower motor
Approx. 12 A at 12 V
S6JB0A7106006
I5JB0A710007-01
1
I5JB0A710008-01
Heater and Ventilation:
Blower Motor Controller Removal and
Installation
Removal
1) Disconnect negative (–) cable at battery.
2) Disable air bag system referring to "Disabling Air
Bag System in Section 8B".
3) Remove glove box.
4) Remove passenger lower member.
5) Disconnect blower motor controller coupler (3).
6) Remove blower motor controller (1) by loosening its
fastening screws (2).
1
Installation
1) Reverse removal procedure.
2) Enable air bag system referring to "Enabling Air Bag
System in Section 8B".
7A-11
S6JB0A7106007
2
3
I5JB0A710009-01