Spare Parts And Accessories; Maintenance And Servicing; Cleaning Sensor Head; Re-Calibration - Beko METPOINT FLM SF53 Installation And Operation Instruction Manual

Thermal flow meter
Hide thumbs Also See for METPOINT FLM SF53:
Table of Contents

Advertisement

EN

7. Spare parts and accessories

The accessories available for the METPOINT
Designation
Power supply with plug-type connector
A
 4032115
High pressure protection device
 4025892

8. Maintenance and servicing

Regularly check the sensor head for dirt and clean it, if necessary. Dirt, dust or oil deposits on the sensor element cause incorrect
measurements.
We recommend checking the sensor element at least once a year. If the compressed air is heavily contaminated, choose a shorter
inspection interval.

9. Cleaning sensor head

To clean the sensor head, immerse it in warm water with a little detergent. Do not clean the sensor with a cloth, sponge, brush or
other implement, as any mechanical impact can destroy the sensor. In the event of persistent deposits, return the sensor to the
manufacturer for inspection and cleaning.

10. Re-calibration

If the device is not custom-configured, we recommend having it calibrated every 12 months. For calibration, send the METPOINT
FLM to BEKO TECHNOLOGIES GmbH.

11. LED display

There is an LED on the top of the METPOINT
15 months to indicate there is an upcoming re-calibration. The flashing LED does not influence measured values. The measurement
signal is still output.
The time interval can be adjusted as requested by the customer in the manufacturing plant.
METPOINT
SF53
®
FLM are listed in the table below.
®
®
FLM housing, which is used to indicate the calibration time. The light flashes after
Installation and operating manual