2
Safety

Standards and directives complied with

2.3 Standards and directives complied with
10 | 48
Ensure that all the points listed under 'Testing and checking the product
functions' are observed.
Do not set controls to normal operation until you have tested and check all the
product functions and handed over the system to the customer.
Testing and checking the product functions
Prevent false triggering of the remote transmission.
If you check building equipment or control devices from external companies,
cooperate with the responsible contact persons.
Neither personal injury nor damage to building equipment should occur when
activating fire controls for test purposes. The following instructions must be
followed:
Use the correct potential (usually that of the building equipment).
Check the controls only as far as the interface (relay with blocking option).
Make sure that only the controls to be tested are activated.
Inform others before testing alarm devices and anticipate that people might
react in panic.
Inform people about possible noise or fog that might occur.
Inform the corresponding alarm and fault receiving stations before testing the
remote transmission.
Modifications to the system design and the products
Modifications to the system and to individual products may lead to faults,
malfunctioning and safety risks. Written confirmation must be obtained from
Siemens and the corresponding safety bodies for modifications or additions.
Modules and spare parts
Components and spare parts must comply with the technical specifications
defined by Siemens. Only use products specified or recommended by
Siemens.
Only use fuses with the specified fuse characteristics.
Wrong battery types and improper battery changing lead to a risk of explosion.
Only use the same battery type or an equivalent battery type recommended by
Siemens.
Batteries must be disposed of in an environmentally friendly manner. Observe
national guidelines and regulations.
Disregard of the safety regulations
Before they are delivered, Siemens products are tested to ensure they function
correctly when used properly. Siemens disclaims all liability for damage or injuries
caused by the incorrect application of the instructions or the disregard of danger
warnings contained in the documentation. This applies in particular to the following
damage:
Personal injuries or damage to property caused by improper use and incorrect
application
Personal injuries or damage to property caused by disregarding safety
instructions in the documentation or on the product
Personal injury or damage to property caused by poor maintenance or lack of
maintenance
A list of the standards and directives complied with is available from your Siemens
contact.
A6V11783979_en--_a