Tools and software Requirements

To service the computer, you need the following:
Torx T-15 screwdriver
Flat-bladed screwdriver (may sometimes be used in place of the Torx screwdriver)
Phillips #2 screwdriver
Diagnostics software
Tamper-resistant T-15 wrench

Screws

The screws used in the computer are not interchangeable. They may have standard or metric threads and
may be of different lengths. If an incorrect screw is used during the reassembly process, it can damage the
unit. HP strongly recommends that all screws removed during disassembly be kept with the part that was
removed, then returned to their proper locations.
CAUTION:
only.
CAUTION:
area to prevent damage.

Cables and connectors

Most cables used throughout the unit are flat, flexible cables. These cables must be handled with care to
avoid damage. Apply only the tension required to seat or unseat the cables during insertion or removal from
the connector. Handle cables by the connector whenever possible. In all cases, avoid bending or twisting the
cables, and ensure that the cables are routed in such a way that they cannot be caught or snagged by parts
being removed or replaced.
CAUTION:
reassembly process. Improper cable placement can damage the computer.

Hard Drives

Handle hard drives as delicate, precision components, avoiding all physical shock and vibration. This applies
to failed drives as well as replacement spares.
If a drive must be mailed, place the drive in a bubble-pack mailer or other suitable protective packaging
and label the package "Fragile: Handle With Care."
Do not remove hard drives from the shipping package for storage. Keep hard drives in their protective
packaging until they are actually mounted in the computer.
Avoid dropping drives from any height onto any surface.
If you are inserting or removing a hard drive, turn off the computer. Do not remove a hard drive while
the computer is on or in standby mode.
Before handling a drive, ensure that you are discharged of static electricity. While handling a drive,
avoid touching the connector.
16
Chapter 4 Routine care, SATA drive guidelines, and disassembly preparation
Metric screws have a black finish. U.S. screws have a silver finish and are used on hard drives
As each subassembly is removed from the computer, it should be placed away from the work
When servicing this computer, ensure that cables are placed in their proper location during the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rp2 2020Rp2 2030

Table of Contents