METPOINT
®
CID
State
Best case
Assess how plausible the
measurement is
Move to the valid distance
range
Move to a different surface 
close to the leak until the
"best case" occurs and the
measurement is robust
Important: The distance measurement can be challenging on black surfaces or in very bright environments, which is
why distances can still be entered manually. To be able to enter manual distances, disable the "Distance by Laser" option.
States:
Best case:
16 | 56
Current distance
measurement
white
yellow
white
red
"Dist:" is green, the distance module measurement is robust and the
distance used falls within the valid range
Outside of range:
Distance measurement = robust, but out of range!
Move to the valid distance range
Original installation and operation manual
Distance parameter
used internally
green
yellow
yellow
empty
Likelihood that the
distance is being
measured correctly
high
medium
high, but distance outside
of valid range
low