Installation Space - Sony Betacam SX DNW-A100 Maintenance Manual

Digital video hybrid recorder
Hide thumbs Also See for Betacam SX DNW-A100:
Table of Contents

Advertisement

1-5. Installation Space

When installing, the installation space must be secured in
consideration of the ventilation and service operation.
. Do not block ventilation (upper lid, right side panel,
lower portion of front panel and bottom plate) and
exhaust part.
. Leave a space around the unit for ventilation.
. Leave a space more than 40 cm at the rear side of the
unit to secure the operation area.
When the unit is installed on the desk or similar condition,
assure that the clearance at the upper and right sides is at
least 4 cm. However, it is recommended that the clearance
above the unit is more than 40 cm in consideration of the
service operation.
Mass DNW-A100/A100P : 38 kg
DNW-A50/A50P
DNW-A45/A45P
n Remove the feet when rack mounting.
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
http://getMANUAL.com
: 38 kg
: 38 kg
481
465
364
31.5
427
Dimensions when Rack-Mounting
When the unit is mounted in the rack, leave a space on the
top and bottom of this unit by 1U.
Moreover, an air flow that is effective in cooling the unit is
essential. If the ventilation is not enough, the unit may be
damaged because an increase of the internal temperature of
the unit can not reduce.
n
This unit is air-cooled by four fans. However for the
operation with the upper lid removed, the air cooling effect
using the fan decreases. Complete the work in a short time
as far as possible when the unit is operated for inspection
with the upper lid removed. Blow a wind using an electric
fan so as to suppress an increase in temperature when the
work is continued for a long time with the power turned
on.
520
(454)
45.5
(47.1)
512.8
577(Maximum traveling distance)
158
104
415.9
15.9
12.7
123.8
263.5
457.5
47.1
454
1-5. Installation Space
18.3
Unit : mm
1-3