Autoloader Power Specifications
Characteristic Specification
Line voltage
60 Hz system: 90 – 265 VAC
50 Hz system: 90 – 265 VAC
Line frequency
47 – 63 Hz
AC Input current
60 Hz system: 4.0 A (RMS) for 115 VAC
50 Hz system: 2.0 A (RMS) for 230 VAC
Power consumption 60 Hz = 75 W; 50 Hz = 80 W
Autoloader Vibration Specifications
Characteristic
Specification
Operating
Swept Sine Vibration 5 – 500 Hz, 0.25 G, 0.254 mm (0.01 inch) to smooth crossover, 1 8ve/min, (X, Y, Z) axes
Random Vibration
0.25 Grms, 5 – 500 Hz (X, Y, Z) axes
Nonoperating
Swept Sine Vibration
5 – 500 Hz, 0.75 G, 0.51 mm (0.02 inch) to smooth crossover, 1 8ve/min, (X, Y, Z) axes
Random Vibration
1.06 Grms, 5 – 500 Hz (X, Y, Z) axes
Autoloader Shock Specifications
Characteristic Specification
Operating
3 G, 5 ms half-sine, 3 pulses (+/–) per axis, X, Y, Z
Nonoperating
20 G, 8 ms half-sine, 3 shocks (+/–) per axis, X, Y, Z
Tape Drive Specifications
LTO-3 Drive Specifications
Description
Read/write transfer rate: maximum sustained
(LTO Ultrium 3 media)
Burst transfer rate
Average access time
Loading time to BOT
(for previously written tape)
Unloading time from BOT
MCBF
Interface type
Media Capacity
Media type
Capacity
LTO Ultrium 3 storage capacity 12800 GB (compressed) with 16 cartridges
Media Specifications
Characteristic
LTO Ultrium 3
LTO Ultrium 3 formatted capacity
Basic description
Dual coat metal particle
Tape length
680 m (2230.9 ft)
Cartridge dimensions
Read compatibility
LTO Ultrium 1, LTO Ultrium 2, LTO Ultrium 3
Write compatibility
LTO Ultrium 2 and LTO Ultrium 3
Shelf life
Cartridge life
1,000,000 passes (any point on the tape passing the recording head in either direction)
LTO Universal Cleaning cartridge life 50 uses
Back to Contents Page
IBM LTO-3
Noncompressed mode: 245 GB/hr
Compressed (2:1 typical): 490 GB/hr
160 MB/s
54 seconds (from BOT)
15 seconds (maximum)
15 seconds (maximum)
> 100,000 cartridge load/unload cycles
Ultra 160 SCSI LVD
400 GB (noncompressed)
800 GB (2:1 typical compression)
10.2 x 10.54 x 2.15 cm
(4 x 4.15 x .85 in)
> 30 years with < 10% loss in demagnetization @ 20°C
40% RH (noncondensing)