Dell PowerVault 124T LTO-3 User Manual page 50

Autoloader
Table of Contents

Advertisement

E9
Time Update Event
Front Panel Error Types
EA
LCD Busy Error
EB
LCD Goto Error
EC
Login/Password Error
ED
Socket Error During SNTP
Barcode Error Types
F0
Bar Code Init Error
F1
Bar Code Hardware Error
F2
Bar Code Baud Rate Error
F3
Bar Code Handshake Error
F4
Bad/Noisy Response From Bar
Code Reader
F5
Checksum Failed
F6
Barcode No Read
F7
Barcode Mismatch Error
F8
Barcode Duplicate Label Error
Diagnostic Error Types
F9
Diagnostic Test Failure
FA
Diagnostic Error, Drive
Reporting Write Protect
FB
Diagnostic Error, Cleaning Tape
Inserted
FC
Diagnostic Load Tape Prompt
FD
Diagnostic Unknown Tape
Format
FE
Diagnostic Invalid Configuration This is an indication that a minimum of two pieces of media are required for test.
The system time was changed. No action required.
Possible LCD controller problem, software error, or communication error.
Power cycle the autoloader.
l
Run the Random Moves test.
l
If all previous steps fail, contact support.dell.com.
l
Incorrect login from front panel.
Use correct login/password.
l
Remove magazines and inspect cartridges. Verify that valid barcode labels are being used on all
l
cartridges, and re-insert the magazines.
If barcode labels are not being used, disable the barcode reader through the Operator Control Panel
l
or Remote Management Unit.
Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
l
Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.
If all previous steps fail, contact support.dell.com.
l
Incomplete barcode label or barcode checksum failed.
Repeat test with new cartridge or label.
l
If problems recur with the original cartridge or label, replace.
l
If all previous steps fail, contact support.dell.com.
l
Barcode label not present.
Apply valid barcode label to cartridge, or disable the barcode reader through the Operator Control
l
Panel or Remote Management Unit.
Power cycle the autoloader.
l
Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
l
Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.
If all previous steps fail, contact support.dell.com.
l
Duplicate barcode.
Power cycle the autoloader.
l
Re-run the failing diagnostic test.
l
If all previous steps fail, contact support.dell.com.
l
Verify that valid, not data protected media is present for test.
l
Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
l
Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.
If all previous steps fail, contact support.dell.com.
l
This is a prompt to manually load a cartridge as required for test.
Verify that valid, not data protected media is present for test.
l
Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
l
Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.
If all previous steps fail, contact support.dell.com.
l
Insure at least two cartridges are present in the autoloader and re-run the failed test.