Siemens 7MB3000 Series Operating Instructions Manual page 84

Wall-mounted device
Table of Contents

Advertisement

Installing / removing and connecting analyzer and option modules
7.11 Installing option modules
Performing installation
Option module OM 2.1
Screw, printed circuit board holder
Printed circuit board holder
Screw, electronics base plate
Figure 7-14
Installing option module, example OM 2.1
1. Loosen the screws
2. Loosen the screw
3. Remove the blanking cover plate for option modules.
4. Insert the option module
Fasten the option module with the two screws
5. Insert the printed circuit board holder
Tighten the screw
6. Fit the electronics base plate
panel of the wall-mounted device.
Tighten the screws
84
Screws for option module (2 units)
Electronics base plate
Screw, electronics base plate
Shielding plate signal lines
and
. Remove the electronics base plate
and remove the printed circuit board holder
into the electronics base plate
with a torque of 2.0 Nm.
with the two screws
and
with a torque of 2.0 Nm.
at the respective slot.
with a torque of 1.3 Nm.
again.
and
at the rear panel and side
Operating Instructions, 07/2023, A5E31930403-AB
.
.
Wall-mounted device

Advertisement

Table of Contents
loading

Table of Contents