Hitachi airPoint Room700 Operation Manual page 13

Advanced color wired remote controller
Table of Contents

Advertisement

No.
Sav
Sav: Low
28
Sav: Med
Sav: High
29
Ext.Sav
30
Main
31
Sub
32
Sub
33
Quick
34
Other remote are in ** setting
Emergency Heating →
35
Alarm Code: **
Auto Clean Unit
36
Mechanic error
Check the unit
37
Cleaning Filter
38
Check
39
Preheating
40
HOT-START
41
Defrost
42
Heat Storage
43
Dust collection **-**
44
Central control
45
Time to OFF(hour)
46
Priority
47
Restrict
(*1) : It depends on the settings of the remote controller.
(*2) : The default setting is cooling: set temperature +2.5°C, heating: set temperature -2.5°C.
If you want to change the correction value for this setback operation, please contact your Hitachi service
agent for assistance with this.
A16381H9HL
Icon
Either the outdoor capacity control, indoor rotation control, or intermittent
operation control is set.
Outdoor capacity control is set on the central controller or outdoor unit.
It does not light when the indoor rotation control or intermittent operation
control of the remote controller is set.
This is the main remote controller.
Use the main remote controller to set the main power savings setting.
In the case of a single unit, this is not displayed.
Sub remote controller is set. Some functions cannot be set from a Sub remote
controller.
There is no main remote controller.
Controls related to power savings and operation noise reduction may not
operate normally.
The operation is in quick mode.
This display blinks when the outdoor unit is operating in a different mode to the
mode set on the controller.
The example above is when "Cool" is set from the remote controller and the
operation mode of the outdoor unit is "Heat".
Emergency Heating Control is in progress.
** indicates the alarm code.
Indicates an error related to the automatic filter cleaning unit(if fitted).
The filter is being automatically cleaned(if fitted).
Indicates an abnormality in the heat storage unit(if fitted).
The compressor cannot be operated because it is preheating.
Preparing for heating operation.
During the defrosting operation, the defrosting light turns on and the indoor fan
stops.
When the operation is stopped during the defrosting operation, the operation
light or the run indicator goes out, but the operation continues and stops after
the defrosting is completed.
It cannot be operated due to the heat storage operation time(if fitted).
It is time to collect dust in the dust box of the automatic filter cleaning unit.
**-** indicates the unit to be collected(if fitted).
Displayed when using the central controller. Remote controller operation is
restricted.
The remaining time of the off timer when the hotel mode is displayed.
Displayed on the main remote controller only in the operation mode or when
there is a setting priority for the operation mode and the set temperature.
At this time, the operation limit lights up on the sub remote controller, and the
operation mode and temperature setting change on the sub remote controller
are restricted.
Displayed on the sub remote controller only when the operation mode or the
operation mode and set temperature setting priority is given.
Description
Conference Room
26
Cool
Other remote are in Heat setting
26
.
5
Temp
Cool
Indicator blinks
3. Operation Method
. 5
Indv.
Fan Speed
Louver
Menu