2.
How to use GeminiEngine Monitor Tool
When this tool is installed, its service resides in the system and monitors the system redundancy
status.
If the status changes to simplex and the FT STATUS LED of the server turns off or illuminates
amber, the tool sounds beeps for a certain interval and displays a dialog box reporting the status
change.
When the server status becomes non-redundant:
GeminiEngine Monitor Tool displays the following dialog box when the system status becomes
simplex:
Buttons:
[Buzzer Stop]:
[Status Check]:
If this dialog box appears even though the status of CPU/IO modules is duplex, the connection
of LANs, built-in SCSI HDDs, or external storage devices connected by FC may not be
duplexed. Check their status.
Notes:
The above dialog box does not appear until you log in to Windows.
The dialog box is displayed on the console screen but not on the remote desktop screen
or terminal service screen.
The dialog box may also appear when the system is temporarily degraded. In such a case,
it is automatically closed when the system status returns to the duplex state and the FT
STATUS LED illuminates green.
If you mistakenly closed the dialog box, run the following file:
C:\ Program Files\NEC\HAS_SW\HASFTSTS\HASFTSTU.EXE
When the dialog box is still displayed after the FT STATUS LED illuminates green, press
the Alt + F4 keys together to close it.
Stops the buzzer (beeps) and closes this dialog box.
Starts the Server Maintenance Utility.
Check the event viewer log and other logs for non-redundancy status.
Installing and Using Utilities 5-91