Replace Batteries
IMPORTANT: Before adjusting the electrical system or
welding on the machine, disconnect the negative (-)
wiring from the battery. If the machine is equipped
with the battery disconnect switch, turn the disconnect
switch OFF.
Your machine has two 12-volt batteries with negative (-)
ground.
If one battery in a 24-volt system has failed but the other is
still good, replace the failed battery with one of the same
type. For example, replace a failed maintenance-free battery
with a new maintenance-free battery. Different types of
batteries may have different rates of charge. This difference
could overload one of the batteries and cause it to fail.
Check Monitor Functions and All Other Instrument
Operation
--- every 10 hours
Run the engine at low idle speed when checking the
instruments.
The monitor indicates alarm, caution and confirmation status
in red, orange, and normal operative condition in blue or
green respectively.
Check each gauge or meter if its needle is moved with the key
switch ON. The needle shall be moved when normal and to the
red range when abnormal.
Refer to the Section of Operator's Station in Chapter 1 for more
information.