Precautions for Communication Terminal

Equipment
This machine is installed with a communication terminal
emitting radio waves behind the operator's seat. There is a
possibility that a medical device, including an implantable
device such as a cardiac pacemaker, could be affected and
malfunction due to the electrical waves emitted from the
communication terminal.
For those who uses medical devices as above should adjust
the operator's seat position to keep the distance between
medical device and the communication terminal are at least
15 centimeters (6 inches) at all times. If this condition cannot
be met, please contact your authorized dealer and have the
person in charge stop the communication terminal from
functioning completely and confirm that no radio waves are
emitted before operating the machine.
The effect of radio waves from communication terminal on
the human body can be evaluated by measuring Specific
Absorption Rate ("SAR"), which is a measure of the amount of
radio frequency energy absorbed by the body when using a
wireless application such as a mobile phone.
All communication terminal installed in this machine comply
with technical standards and international guidelines
regarding the absorption of radio waves by the human body.
There are two SAR measurement method and the safety
standards, 2.0 W/kg (measured by 10 g per unit) and 1.6 W/kg
(measured by 1 g per unit), either one is adopted depending
on the country.
This machine is equipped with a communication terminal
model HPRO-100, HPRO-4G, or QConnect. Consult your
authorized dealer for the model of communication terminal.
Specific Absorption Rate ("SAR") of communication terminal.
The values in ( ) are based on Taiwanese regulations.
HPRO-100
1.6 W/kg (1 g/unit)
0.51 W/kg
2.0 W/kg (10 g/unit) 0.12 W/kg
This data was measured by having each type of
communication terminal used with this machine, and a human
body set apart by 3 centimeters (1.18 inches).
Precautions in Taiwan*: Under the Taiwanese regulations, the
maximum SAR value is set as the standard value 2 W/kg. The
actual measurement value is 0.25 W/kg using QConnect, and
0.31 W/kg using HPRO-4G.
SAFETY
HPRO-4G*
QConnect *
0.91 W/kg
-
0.50 W/kg
-
(0.31 W/kg)
(0.25 W/kg)
S-38
MNEC-01-046