Check Refrigerant

--- every 6 months
Start the engine and run at approximately 1500 min
Turn the air conditioner switch to ON. Set the blower switch
to HI and set the temperature control switch to the coolest
position (18 °C on the monitor screen). Operate the air
conditioner 2 to 3 minutes. Check if cool air comes out from
the vent in the cab.
Type
Refrigerant No.
HFC
R134a
IMPORTANT: If recovery or refill of refrigerant is required
during the machine maintenance (including disposing
the machine), contact your refrigerant supplier or your
authorized dealer.

Check Compressor and Pulley

--- once a year
Check the compressor and its vicinity for abnormality in
operation, oil stain, or refrigerant leakage. Check the pulley for
abnormal noise.
Check the belt for abnormal deflection and damage.
Check Compressor:
After operating the air conditioner for 5 to 10 minutes,
check temperature at both the high pressure pipe and the
low pressure pipe.
Normally, the high pressure pipe must be hot and the low
pressure pipe must be cool.
MAINTENANCE
(rpm).
-1
Quantity kg (lb)
0.8±0.05
(1.76±0.11)
7-102
Compressor
MPTC-07-013