Unpacking the device

When unpacking the device, do the following:
1.
2.
3.
Note
If any item is missing or damaged, contact Siemens for assistance.
2.3

Mounting the device

The RUGGEDCOM MX5000 is designed for maximum mounting and display
flexibility. It can be equipped with adapters that allow it to be installed in a 48 cm (19
in) rack or directly on a panel.
Heat dissipation
Heat generated by the device is channeled outwards from the enclosure. As such, it
is recommended that 2.5 cm (1 in) of space be maintained on all open sides of the
device to allow for some convectional airflow.
RUGGEDCOM MX5000
Equipment Manual, 11/2023, C79000-G8976-1059-16
Mount the device.
For more information, refer to "Mounting the device" (Page 15).
Connect the failsafe alarm relay.
For more information, refer to "Connecting the Failsafe Alarm
Relay" (Page 21).
Connect power to the device and ground the device to safety Earth.
For more information, refer to "Grounding the device" (Page 19) and
"Connecting Power" (Page 22).
Secure all wires.
Secure all wires from the terminal blocks so they cannot be disturbed by casual
contact. For example, in rack mount installations, use tie wraps to secure the
wires to the rack.
Connect the device to the network.
For more information, refer to "Communication ports" (Page 31).
Configure the device.
For more information, refer to "Configuring the Device" (Page 39).
Inspect the package for damage before opening it.
Visually inspect each item in the package for any physical damage.
Verify all items are included.