Siemens SIMATIC NET RUGGEDCOM MX5000 Equipment Manual page 60

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM MX5000:
Table of Contents

Advertisement

IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
EC 60225-27
a
Siemens-specified severity levels
IEEE 1613 EMC Type Tests
Note
RUGGEDCOM products meet Class 1 requirements for copper Ethernet
configurations and Class 2 for fiber Ethernet configurations. Class 1 allows for
temporary communication loss, while Class 2 requires error-free and interrupted
communications.
RUGGEDCOM MX5000
Equipment Manual, 11/2023, C79000-G8976-1059-16
Test
Damped Oscillatory
Mains Frequency
Voltage
Ripple on DC
Power Supply
Dielectric Strength
HV Impulse
Description
ESD
Radiated RFI
Fast Transient
Oscillatory
HV Impulse
6.3 EMC and Environmental Type Tests
Description
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
DC Power ports
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
AC Power ports
Earth ground ports
Signal ports
DC Power ports
AC Power ports
Signal ports
Certification
Test Levels
2.5 kV common, 1 kV
differential mode @1 MHz
2.5 kV common, 1 kV
differential mode @1MHz
2.5 kV common, 1 kV
differential mode @1MHz
30 V Continuous,
300 V for 1 s
30 V Continuous,
300 V for 1 s
10%
2 kV (Fail-Safe
Relay output)
2 kV
2 kV
5 kV (Fail-Safe
Relay output)
5 kV
5 kV
Test Levels
+/-2 kV, +/-4 kV, +/- 8 kV
+/-4 kV, +/-8 kV, +/-15 kV
35 V/m
+/- 4 kV @ 2.5 kHz
+/- 4 kV
+/- 4 kV
+/- 4 kV
2.5 kV common mode @1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
5 kV (Fail-Safe Relay output)
Severity
Levels
3
3
3
4
4
3
 
 
 
 
 
 
51