(4)
Frequency setting signal (current) bias/gain adjustment method
(a) Method to adjust any point without application of a voltage (current) to across terminals 2-5 (4-5).
Operation
1.
Confirmation of the RUN indication and
operation mode indication
The inverter should be at a stop.
The inverter should be in the PU operation
mode.
(Using
)
2.
Press
to choose the parameter setting
mode.
3.
Turn
until
appears.
4.
Turn
until
appears.
5.
Turn
until
(
Set to C4 Terminal 2 frequency setting gain.
6.
Press
to display the analog voltage
(current) value (%).
7.
Apply a 5V (20mA) voltage (current).
(Turn the external potentiometer connected
across terminals 2-5 (across terminals 4-5) to
maximum (any position).)
NOTE
After performing operation in step 6, do not touch
8.
Press
to set.
Turn
to read another parameter.
Press
to return to the
Press
twice to show the next parameter (
REMARKS
If the frequency meter (display meter) connected across the terminals AM-5 does not indicate just 60Hz, set the calibration
parameter C1 AM terminal calibration. (Refer to page 152)
Frequency setting by analog input (terminal 2, 4)
PRM indication is lit.
(The
appears.)
) appears.
Terminal 2 input is
selected
* The value is nearly 100 (%) in the maximum position of
the potentiometer.
Flicker...Parameter setting complete!!
* The value is nearly 100 (%) in the maximum position of
the potentiometer.
indication (step 4).
Display
parameter
number
read
C0 to C41 setting
is enabled.
Terminal 4 input is
selected
Analog voltage (current)
value (%) across terminals 2-
5 (across terminals 4-5)
until completion of calibration.
Terminal 2 input is
selected
).
previously
Terminal 4 input is
selected
173
4